Installation of the hardware
Note
During the installation process you must at all times take the provisions of into account.
Model OM1
Hardware Installation
Wall-mounted


During the installation process you must at all times take the provisions of into account.


The SmartgridOne Controller has a hole pattern of 80mm x 63mm (W x H).
The screw head should not exceed a diameter of 7mm (e.g., a universal screw of 4 x 40mm is recommended).
For a flush mount, ensure the screws protrude no more than 8mm from the wall.


DIN-rail mounts need to be ordered seperately.
The SmartgridOne Controller requires a 12V (2A) DC power supply connected via a 5.5mm jack. The required power adapter is included in the delivery package.
See the supported device guides and the wiring & connectivity guidelines for the connection of devices.
The SmartgridOne Controller must always be connected to a wired (RJ45) network interface to ensure reliable communication and functionality. See also the wiring & connectivity guidelines.