SmartgridOne logo
SmartgridOne logo
Acessórios
AplicativoAvisos de segurança, manutenção e legais
Caixa de Ferramentas
Certificados
Configuração de A a Z
ControladorDiretrizes para fiação e conectividade
Dispositivos
Bomba de Calor
Caldeira
Cargas Comutadas
Estação de Carregamento para Veículos Elétricos
Inversores Híbridos Fotovoltaicos e de Bateria
a-TroniXABB, FIMERADS-TecAforeAlphaESSAlpvoltAmpowrAngileAPsystems
Autarco
Bateria AtepsBateria-CBattlinkBeauventCellpowerDanfossDeltaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEquipamento EPEVEFairlandFortona
Foxess
FraxFroniusGoodWeGotionGravaçãoGreener / Alfen
Growatt
Growatt Série MINSérie Growatt MICSérie Growatt MIDSérie Growatt MODSérie Growatt SPASérie Growatt SPHSérie Growatt UESérie Growatt WIT
HiteHithium
Huawei
Hypontech
Hyxipower
Inversores DMEGCInversores ESYInversores Fotovoltaicos, Híbridos e de Bateria AnklousInversores Fotovoltaicos, Híbridos e de Bateria DET PoweriWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerRecondicionamentoRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H até SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Medidor de Água
Medidor de Energia
Medidor de Gás
Novas integrações
Nuvem
Plc
Especificações
Específico para o Cliente
Início RápidoInstalaçãoLEDs de StatusLicençaRede
Resolução de Problemas
Sinais Externos
Tempo de resposta do controleTutoriais em vídeo
DispositivosInversores Híbridos Fotovoltaicos e de BateriaGrowatt
logo

Dispositivos Suportados

Device TypeManualModbus TCP (Ethernet)RS485Curtailment
MIN 2500-6000TL-XManual❌✅✅
MIN 2500-6000TL-XHManual
MIN 7000-10000TL-XManual
MIN 7000-10000TL-X2Manual

Cabeamento

RS485 - MIN 2500-6000TL

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485 A1RS485 ARS485_POSRS485 ATX+
RS485 B1RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image

RS485 - MIN 7000-10000TL

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485 A1RS485 ARS485_POSRS485 ATX+
RS485 B1RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image
Image
Aviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Growatt

Previous Page

Série Growatt MIC

Next Page

On this page

Dispositivos SuportadosCabeamentoRS485 - MIN 2500-6000TLRS485 - MIN 7000-10000TL