SmartgridOne logo
SmartgridOne logo
Accessori
AppAvvertenze di sicurezza, manutenzione e legaliAvvio rapido
Cassetta degli attrezzi
Certificati
Configurazione dalla A alla Z
Controllore
Dispositivi
Caldaia
Carichi commutati
Cloud
Contatore del gas
Contatore dell'acqua
Contatore di Energia
Inverter Ibridi Fotovoltaici e per Batterie
a-TroniXABB, FIMERADS-TecAlphaESSAmpowrAngileApparecchiature EPAPsystems
Autarco
Batteria AtepsBeauventC-BatteryCellpowerChisageDanfossDeltaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEVEFortona
Foxess
FoxESS GMAXFoxESS Serie HFoxESS Serie R
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
Inverter DMEGCInverter ESYInverter Fotovoltaici, Ibridi e a Batteria DET PowerInverter Fotovoltaici, Ibridi e per Batterie AnklousiWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPrimaPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H fino a SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Nuove integrazioni
Plc
Pompa di calore
Stazione di Ricarica EV
InstallazioneLED di statoLicenzaLinee guida per cablaggio e connettivitàRete
Risoluzione dei problemi
Segnali Esterni
Specifiche
Specifico del Cliente
Tempo di risposta del controlloVideo tutorial
DispositiviInverter Ibridi Fotovoltaici e per BatterieFoxess
logo

Dispositivi Supportati

Device TypeModbus TCP (Ethernet)RS485CurtailmentMinimum device firmware version
H3 (Non-Pro, Non-Smart): → ❗Vedi nota sotto ❗❌✅❗(vedi sotto)Master: 2.05, Manager: 1.85 (*)
H3 AIO (All-In-One)✅❌Master: 1.33, Manager: 1.37 (*)
H3-Smart⌛ (in sviluppo)Master: 1.25, Manager: 1.14 (*)
H3-ProMaster: 1.62, Manager: 1.34 (*)
H1(sperimentale, richiede test)Master: 1.70, Manager: 1.78 (*)
H1-G2⌛ (in sviluppo)Master: 1.40, Manager: 1.54 (*)
P3-SH✅ (sperimentale)✅ (sperimentale)Master: 1.62, Manager: 1.34 (*)
Attenzione
Attenzione

H3 (Non-Pro, Non-Smart)

L'H3 (Non-Pro, Non-Smart) utilizza un protocollo di comunicazione differente a seconda della versione 'master' e 'manager' dell'inverter. Scegliere l'integrazione corrispondente in base alle versioni software dell'inverter.

✅ Il Curtailment è supportato per le versioni firmware master v.2.05 e manager v.1.85 e inferiori.

⌛ Il Curtailment è in sviluppo per le versioni firmware master v.2.06 e manager v.1.86 e superiori.

Avviso
Avviso

La serie H3 (non-pro, non-smart) utilizza un protocollo di comunicazione differente rispetto alle serie H3 Pro e H3 Smart. Pertanto, quando si seleziona il tipo di dispositivo in SmartgridOne Controller, è necessario essere molto certi di scegliere il tipo corretto.

Nota
Nota

Versioni firmware supportate

(*) L'integrazione potrebbe funzionare anche con versioni firmware più vecchie, ma queste non sono state testate.

Image 1

Cablaggio

Avviso
Avviso

L'indirizzo modbus predefinito, o ID dispositivo, è 247. Tenerne conto durante la scansione di un inverter. È possibile modificare gli indirizzi di bus minimo e massimo che il controller scansionerà nei parametri di scansione.

Ethernet

Per un cablaggio ethernet corretto: seguire le linee guida per il cablaggio ethernet.

Avviso
Avviso

Non è possibile connetterlo tramite dongle WiFi.

RS485

L'inverter può essere collegato al SmartgridOne Controller tramite RS485. Questo avviene tramite il connettore [J] nell'immagine sottostante.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Logger 485A / pin 1RS485 ARS485_POSRS485 ATX+
Logger 485B / pin 2RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image 1

RS485 H3 Pro

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
EMS 485A / pin 17RS485 ARS485_POSRS485 ATX+
EMS 485B / pin 18RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image 1

Configurazione per H3 (Non-Pro, Non-Smart) e H1-G2

1. Attivazione monitoraggio e gestione inverter

Il controllo deve essere attivato tramite l'inverter, e il contatore deve essere disattivato. Questo si fa tramite il display nel menu Feature Parm. Per prima cosa, aprire il menu Feature Parm come segue:

  1. Andare al Menu.
Image 1
  1. Inserire la password. La predefinita è 0000.
Image 1
  1. Selezionare Impostazioni.
Image 1
  1. Selezionare Feature Parm.

2. Attivazione del controllo remoto

Utilizzare il display, partendo dalla pagina Feature, per attivare il controllo seguendo i seguenti passi:

  1. Selezionare Remote control.
Image 1
  1. Impostarlo su Enable.
Image 1

3. Disattivazione del contatore

Il contatore deve essere disattivato. Il controllo sarà preso in carico dal SmartgridOne Controller. Pertanto, il contatore non deve essere collegato all'inverter ma al SmartgridOne Controller. Per disattivare il contatore nelle impostazioni, seguire questi passaggi:

  1. Tornare alla pagina Feature.
  2. Selezionare Meter1.
Image 1
  1. Selezionare Set.
Image 1
  1. Impostarlo su Disable.
Image 1

4. Impostazione indirizzo inverter

L'indirizzo dell'inverter può essere impostato anche tramite il display.

  1. Andare al menu Impostazioni come descritto sopra.
  2. Selezionare Communication.
  3. Selezionare RS485.
  4. Selezionare Device ID.
  5. Impostare l’ID dispositivo sull'indirizzo desiderato. Se si collegano più dispositivi allo stesso bus RS485, è necessario assegnare a ciascuno un indirizzo univoco.
Image 1
Suggerimento
Suggerimento

Scansione più veloce

Il SmartgridOne Controller inizia la scansione dall'indirizzo 1 di default. Scegliere un indirizzo più basso permetterà di trovare l'inverter più rapidamente.

Avviso
Avviso

Più inverter

Se si dispone di più inverter, è importante impostare indirizzi paralleli diversi, ogni inverter deve avere un indirizzo diverso.

Configurazione per H3-smart e H3-Pro

Il controllo remoto è attivato di default, non è necessario modificare alcuna impostazione.

La modifica dell'indirizzo inverter (o ID dispositivo) può essere effettuata allo stesso modo dell'H3 (vedi sopra).

FoxESS GMAX

Previous Page

FoxESS Serie R

Next Page

On this page

Dispositivi SupportatiH3 (Non-Pro, Non-Smart)Versioni firmware supportateCablaggioEthernetRS485RS485 H3 ProConfigurazione per H3 (Non-Pro, Non-Smart) e H1-G21. Attivazione monitoraggio e gestione inverter2. Attivazione del controllo remoto3. Disattivazione del contatore4. Impostazione indirizzo inverterScansione più velocePiù inverterConfigurazione per H3-smart e H3-Pro