SmartgridOne logo
SmartgridOne logo
Acessórios
AplicativoAvisos de segurança, manutenção e legais
Caixa de Ferramentas
Certificados
Configuração de A a Z
ControladorDiretrizes para fiação e conectividade
Dispositivos
Bomba de Calor
Caldeira
Cargas Comutadas
Estação de Carregamento para Veículos Elétricos
Inversores Híbridos Fotovoltaicos e de Bateria
Medidor de Água
Medidor de Energia
ABBAccuenergyAcrelAlgodueAnexoBMR
Carlo Gavazzi
ChargeeChintDados do Medidor em NuvemDornscheidt
Eastron
Eniris
FluviusFroniusHagerHomeWizardHuaweiIneproIskra
Janitza
JoulzKaifaKamstrupLandis+GyrLegrandLitiotM-BusMedidor Zendure P1Medidores de energia ShellyMetcomP1ApiPhoenix-ContactPilotoPronto para rede inteligenteSagemcom
Schneider
ComPact NSXMasterPact MTZPM 3250PM 8000PowerTag EnergiaSérie IEM 2100Série IEM 2100Série IEM 3000Série PM 800Série PM 5000
Self configured energy meterSeneca S604SessySiemensSmappeeSocomecSolax
Solis
SunwodaTillquistVictronWeidmüllerWhatWattYouLessZiv
Medidor de Gás
Novas integrações
Nuvem
Plc
Especificações
Específico para o Cliente
Início RápidoInstalaçãoLEDs de StatusLicençaRede
Resolução de Problemas
Sinais Externos
Tempo de resposta do controleTutoriais em vídeo
DispositivosMedidor de EnergiaSchneider

Schneider-Electric Medidor de Energia PM 8000

logo

Dispositivos Suportados

Device TypeModbus TCP (Ethernet)RS485
Schneider-Electric PM 8000✅✅
Image 1

Fiação

Ethernet

Para uma fiação ethernet correta: siga as diretrizes para fiação ethernet.

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Terminal 22 / +RS485 ARS485_POSRS485 ATX+
Terminal 23 / -RS485 BRS485_NEGRS485 BTX-
Terminal 25 / CRS GNDGNDNot availableG
Image 1

Configuração

Ethernet

Consulte o manual do dispositivo.

RS485

Aviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Consulte o manual do dispositivo para saber como alterar o endereço Modbus.

PM 3250

Medidor de Energia Schneider-Electric PM 3250

PowerTag Energia

Sensores de Energia PowerTag da Schneider-Electric

On this page

Dispositivos SuportadosFiaçãoEthernetRS485ConfiguraçãoEthernetRS485