SmartgridOne logo
SmartgridOne logo
AppCertificates
Control response time
New integrationsOverview
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, Hybrid and Battery InvertersAPsystemsAteps Battery
Autarco
BeauventC-BatteryCellpowerChisageDanfossDeltaDET Power PV, Hybrid and Battery InvertersDEYEDiehl-AkoDMEGC InvertersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentESY InvertersFortona
FraxFroniusGoodWeGotionGreener / Alfen
HiteHithium
Hypontech
iWellJinkoKacoKehuaKostal
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H till SE6000HSessySigenergySinexcel
Socomec
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solis Grid-tied Inverters
Solis Hybrid Inverters
3t10K-HVES-G5 WiringS-Series-Hybrid
Solplanet
SunwaytechSunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZeversolar
InstallationLicenseNetworkQuick StartSafety, maintenance and legal noticesSpecificationsStatus LEDs
Video tutorialsWiring & connectivity guidelines
DevicesPV hybrid and battery invertersSolisSolis Hybrid Inverters
logo

This page describes the communication with a Solis 3T10K over Modbus-RTU (rs485). By default, the inverter is set to address 1. This can be changed via the display of the inverter. You can find the procedure in chapter 7.3.2 of the manual. The RS485 terminals are located on the bottom of the inverter behind a protective plate.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Pin 3RS485 ARS485_POSRS485 ATX+
Pin 4RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image
Warning
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.