Ilumen charging stations
Supported Devices
| Device Type | Variants | Modbus TCP (Ethernet) | RS485 |
|---|---|---|---|
| Ilumen | / | ✅ | ❌ |
| Device Type | Variants | Modbus TCP (Ethernet) | RS485 |
|---|---|---|---|
| Ilumen | / | ✅ | ❌ |
For communication with Eniris (Modbus TCP) the Ilumen charging station must be connected to a local IP network.
Port 502 (Modbus TCP) is commonly used across the network. Ensure firewall rules allow TCP traffic between the Eniris gateway and the charger's IP on port 502. Do NOT expose port 502 to the public internet.
Ilumen devices supported by this driver communicate over Modbus TCP only. RS485/Modbus RTU is not supported by the Ilumen driver described here.
| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| Not applicable | RS485 A | RS485_POS | RS485 A | TX+ |
| Not applicable | RS485 B | RS485_NEG | RS485 B | TX- |
| Not applicable | RS GND | GND | Not available | G |
Follow these steps to enable Modbus TCP communication between an Ilumen charging station and the Eniris gateway. The steps assume the charger is already powered and reachable on the local network.
Access the charge station network configuration:
Network settings:
Modbus TCP server settings:
The Ilumen driver in Eniris expects Modbus slave IDs in the 1–247 range. Use a unique ID on the network to avoid collisions with other Modbus/TCP devices.
Ensure the device is reachable:
Configure the Eniris gateway:
Match communication parameters:
Discovery and verification: