DevicesPV hybrid and battery invertersGrowatt
Supported Devices
| Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment |
|---|---|---|---|
| MIC 600TL-X | ❌ | ✅ | |
| MIC 750TL-X | ✅ | ||
| MIC 1000TL-X | |||
| MIC 1500TL-X | |||
| MIC 2000TL-X | |||
| MIC 2500TL-X | |||
| MIC 3000TL-X | |||
| MIC 3300TL-X |

| Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment |
|---|---|---|---|
| MIC 600TL-X | ❌ | ✅ | |
| MIC 750TL-X | ✅ | ||
| MIC 1000TL-X | |||
| MIC 1500TL-X | |||
| MIC 2000TL-X | |||
| MIC 2500TL-X | |||
| MIC 3000TL-X | |||
| MIC 3300TL-X |

| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| RS485 A1 | RS485 A | RS485_POS | RS485 A | TX+ |
| RS485 B1 | RS485 B | RS485_NEG | RS485 B | TX- |
| N/A | RS GND | GND | Not available | G |
By default, the inverter is set to address 1. This can be changed via the settings menu of the inverter. This is only necessary if several devices are connected to the RS485 communication bus.
You can change the address of the inverter via the touch control. It works as follows:
| Touch control | Impact |
|---|---|
| Touch once | Change display or number + 1 |
| Touch twice | Enter or confirm |
| Touching three times | Previous menu |
| Keep touched for 5 seconds |
|
Change the address by going to the "Set Comaddr" menu as shown in the image to the left or above. Set the address to a unique value. See Chapter 7 of the inverter manual for more information.